Decision Summary

Upload-ready calibration protocol overview
Instrument P70s1
Session 3
Location ChapelHillNC
Calibration person Alexander Kotsakis
CF file Pandora70s1_CF_v1d20190917.txt
Software version 1.8.19
Calibration vector -
Reference day -
Overall status development
O3Ext: Not answeredO3Synt: Not answeredNO2: Not answeredSO2: Not answeredHCHO: Not answeredH2O: Not answered
Instrument P70s1
Session 3
Events 133
Figures 1
Action time 23m 31s

Action Timeline

25 action intervals
Jun 17, 202002:11 PM03:35 PMCheckDispersionCreateReferenceAssignCalFileCheckDispersion 1m 4s abortedCheckDispersion 3s finishedCheckDispersion 30s abortedCheckDispersion 5s finishedCheckDispersion 36s finishedCheckDispersion 4s finishedCheckDispersion 0s abortedCheckDispersion 33s abortedCheckDispersion 26s finishedCheckDispersion 3s finishedCheckDispersion 0s abortedCheckDispersion 29s finishedCheckDispersion 3s finishedCheckDispersion 0s finishedCheckDispersion 44s finishedCheckDispersion 3s finishedCheckDispersion 0s finishedCreateReference 16m 6s finishedCreateReference 0s finishedCreateReference 0s finishedCreateReference 0s abortedCreateReference 1m 2s finishedCreateReference 0s finishedCreateReference 0s finishedAssignCalFile 1m 39s finished

Duration by Step

CreateReference17m 8sCheckDispersion4m 44sAssignCalFile1m 39s

Action Summary

Action Events Runs Aborted Time
AssignCalFile 4 1 0 1m 39s
CheckDispersion 47 17 5 4m 44s
CreateReference 75 7 1 17m 8s
No action 7 0 0 0s

Session Figures

1 figure from Google Drive/figures
calprotocol section

Wavelength Calibration

Slit function parameters

Pandora70s1_WavelengthCalibration_SlitFuncParam (1).jpeg - 123 KB
Slit function parameters

Automatically harvested metadata

Automatically Harvested Metadata

Manual review and decision

Manual Review and Decision

Calibration notes, data-quality findings, and whole-period evaluation.

Data Evaluation

Could there be an offset between VPs?

No

Are there breakpoint-analysis plots or suspicious discontinuities?

No

Do daily figures before and after the new VP look consistent?

No

Is there an AMF dependency for one or more VPs?

No

Is there seasonality, for example negative values in winter?

No

Does the daily shape follow the trop data roughly?

No

If there is a discrepancy, what are the DS and Sky viewing directions?

No

Is there a co-located or nearby instrument for comparison?

No

O3Ext

Decision for O3Ext

O3Synt

Decision for O3Synt

NO2

Decision for NO2

SO2

Decision for SO2

HCHO

Decision for HCHO

H2O

Decision for H2O