Decision Summary

Upload-ready calibration protocol overview
Instrument P54s1
Session 26
Location Seoul
Calibration person Markus Kilian
CF file Pandora54s1_CF_v26d20211117.txt
Software version 1.8.73
Calibration vector calV1
Reference day -
Overall status development
O3Ext: With CareO3Synt: With CareNO2: YesSO2: YesHCHO: YesH2O: Yes
Instrument P54s1
Session 26
Events 143
Figures 16
Action time 26m 49s

Action Timeline

32 action intervals
Jan 29, 202509:14 AM11:27 AMCreateReferenceFieldCalibrationAssignCalFileCreateReference 1s abortedFieldCalibration 2m 16s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 11m 21s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 37s abortedFieldCalibration 31s finishedFieldCalibration 0s abortedFieldCalibration 5m 9s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 5m 38s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedAssignCalFile 31s finishedCreateReference 16s abortedCreateReference 1s abortedFieldCalibration 27s aborted

Duration by Step

FieldCalibration26m 0sAssignCalFile31sCreateReference18s

Action Summary

Action Events Runs Aborted Time
AssignCalFile 3 1 0 31s
CreateReference 6 3 3 18s
FieldCalibration 121 28 3 26m 0s
No action 13 0 0 0s

Session Figures

16 figures from Google Drive/figures
reference period

Reference Day Decision Support

Upload the FOV and L0 raw-count evidence used to justify the selected reference day before reviewing the CreateReference figures.

calprotocol section

Reference Period and CreateReference

Create reference L1CHARFILT

Pandora54s1_CreateReference_L1CHARFILT_OPEN_U340.jpeg - 123 KB
Create reference L1CHARFILT

Create reference SELSPECS

Pandora54s1_CreateReference_SELSPECS_OPEN_U340.jpeg - 81 KB
Create reference SELSPECS

Create reference SLERR (STRAY)

Pandora54s1_CreateReference_SLERR(STRAY)_OPEN_U340.jpeg - 84 KB
Create reference SLERR (STRAY)

Create reference AODEST

Pandora54s1_CreateReference_AODEST.jpeg - 46 KB
Create reference AODEST

Create reference SENSCORRFIN (SENS)

Pandora54s1_CreateReference_SENSCORRFIN(SENS)_OPEN_U340.jpeg - 85 KB
Create reference SENSCORRFIN (SENS)

Create reference DISPFIT (DISP)

Pandora54s1_CreateReference_DISPFIT(DISP).jpeg - 77 KB
Create reference DISPFIT (DISP)

Create reference WLCHANGE (DISP)

Pandora54s1_CreateReference_WLCHANGE(DISP)_OPEN_U340.jpeg - 89 KB
Create reference WLCHANGE (DISP)

Create reference SHIFT (CLOS)

Pandora54s1_CreateReference_SHIFT(CLOS)_OPEN_U340.jpeg - 114 KB
Create reference SHIFT (CLOS)
field calibration

O3

FieldCalibration VC O3

Pandora54s1_FieldCalibration_VC_O3.jpeg - 71 KB
FieldCalibration VC O3

FieldCalibration SCREFINT O3

Pandora54s1_FieldCalibration_SCREFINT_O3.jpeg - 52 KB
FieldCalibration SCREFINT O3
field calibration

NO2

FieldCalibration MLE NO2

Pandora54s1_FieldCalibration_MLE_NO2.jpeg - 120 KB
FieldCalibration MLE NO2

FieldCalibration VCMLE NO2

Pandora54s1_FieldCalibration_VCMLE_NO2.jpeg - 81 KB
FieldCalibration VCMLE NO2
field calibration

SO2

SO2 MLE settings applied fw1out=(); fw2out=(); dqf2in=(); ddlim=(-1.000,-1.000); shilim(nm)=(-0.050,0.050); uscmax=1.461e-02; wrmsmax=9.000e-04; atvarmax(%)=4.000e+01; amflim=(1.000,2.500); amflimvar=(0.000,1.000); perc=0.00; ngroup=10; timeaver(min)=0.00; redu=0; scref=(1.004e-04); uscref=(8.554e-05)

FieldCalibration MLE SO2

Pandora54s1_FieldCalibration_MLE_SO2.jpeg - 64 KB
FieldCalibration MLE SO2

FieldCalibration VCMLE SO2

Pandora54s1_FieldCalibration_VCMLE_SO2.jpeg - 55 KB
FieldCalibration VCMLE SO2
field calibration

HCHO

HCHO E-MLE settings applied fw1out=(); fw2out=(); dqf2in=(); ddlim=(-1.000,-1.000); shilim(nm)=(-0.050,0.050); uscmax=3.714e-04; wrmsmax=9.000e-04; atvarmax(%)=4.000e+01; amflim=(1.000,5.000); amflimvar=(0.000,1.000); perc=50.00; ngroup=10; timeaver(min)=0.00; redu=2; scref=(1.756e-04); uscref=(2.397e-05)

FieldCalibration MLE HCHO

Pandora54s1_FieldCalibration_MLE_HCHO.jpeg - 67 KB
FieldCalibration MLE HCHO

FieldCalibration VCMLE HCHO

Pandora54s1_FieldCalibration_VCMLE_HCHO.jpeg - 75 KB
FieldCalibration VCMLE HCHO

Automatically harvested metadata

Automatically Harvested Metadata

Manual review and decision

Manual Review and Decision

Calibration notes, data-quality findings, and whole-period evaluation.

Data Evaluation

Could there be an offset between VPs?

No

Are there breakpoint-analysis plots or suspicious discontinuities?

No

Do daily figures before and after the new VP look consistent?

No

Is there an AMF dependency for one or more VPs?

No

Is there seasonality, for example negative values in winter?

No

Does the daily shape follow the trop data roughly?

No

If there is a discrepancy, what are the DS and Sky viewing directions?

No

Is there a co-located or nearby instrument for comparison?

No

O3Ext

Decision for O3Ext
With Care
O3Synt looks good. O3Ext almost everything flagged out

O3Synt

Decision for O3Synt
With Care

NO2

Decision for NO2
Yes
looks good, E-MLE used

SO2

Decision for SO2
Yes
looks good, few days with inverse u-shape

HCHO

Decision for HCHO
Yes
looks good, E-MLE used

H2O

Decision for H2O
Yes
looks good