Decision Summary
Upload-ready calibration protocol overview
Instrument
P29s1
Session
11
Location
-
Calibration person
Stefanie Morhenn
CF file
Pandora29s1_CF_v11d20170504.txt
Software version
1.8.75
Calibration vector
CalV2
Reference day
-
Overall status
development
O3Ext: YesO3Synt: UnusableNO2: YesSO2: YesHCHO: UnusableH2O: Yes
Action Timeline
9 action intervalsDuration by Step
Action Summary
| Action | Events | Runs | Aborted | Time |
|---|---|---|---|---|
| AssignCalFile | 3 | 1 | 0 | 55s |
| CreateReference | 2 | 1 | 1 | 1s |
| FieldCalibration | 12 | 7 | 1 | 11m 34s |
| No action | 13 | 0 | 0 | 0s |
Session Figures
17 figures from Google Drive/figures
calprotocol section
Wavelength Calibration
reference period
Reference Day Decision Support
Upload the FOV and L0 raw-count evidence used to justify the selected reference day before reviewing the CreateReference figures.
calprotocol section
Reference Period and CreateReference
Create reference L1CHARFILT
Pandora29s1_CreateReference_L1CHARFILT_OPEN_U340.jpeg - 164 KBCreate reference SELSPECS
Pandora29s1_CreateReference_SELSPECS_OPEN_U340.jpeg - 132 KBCreate reference SLERR (STRAY)
Pandora29s1_CreateReference_SLERR(STRAY)_OPEN_U340.jpeg - 115 KBCreate reference AODEST
Pandora29s1_CreateReference_AODEST.jpeg - 65 KBCreate reference SENSCORRFIN (SENS)
Pandora29s1_CreateReference_SENSCORRFIN(SENS)_OPEN_U340.jpeg - 114 KBCreate reference DISPFIT (DISP)
Pandora29s1_CreateReference_DISPFIT(DISP).jpeg - 109 KBCreate reference WLCHANGE (DISP)
Pandora29s1_CreateReference_WLCHANGE(DISP)_OPEN_U340.jpeg - 123 KBCreate reference SHIFT (CLOS)
Pandora29s1_CreateReference_SHIFT(CLOS)_OPEN_U340.jpeg - 134 KB
field calibration
O3
field calibration
NO2
field calibration
SO2
field calibration
HCHO
Automatically harvested metadata
Automatically Harvested Metadata
Manual review and decision
Manual Review and Decision
Calibration notes, data-quality findings, and whole-period evaluation.Data Evaluation
Could there be an offset between VPs?
No
Are there breakpoint-analysis plots or suspicious discontinuities?
No
Do daily figures before and after the new VP look consistent?
No
Is there an AMF dependency for one or more VPs?
No
Is there seasonality, for example negative values in winter?
No
Does the daily shape follow the trop data roughly?
No
If there is a discrepancy, what are the DS and Sky viewing directions?
No
Is there a co-located or nearby instrument for comparison?
No
O3Ext
Decision for O3Ext
Yes
O3T taken from climatology (cto0 was 20 K above clim)
O3Synt
Decision for O3Synt
Unusable
NO2
Decision for NO2
Yes
looks good
SO2
Decision for SO2
Yes
looks good
HCHO
Decision for HCHO
Unusable
too high
H2O
Decision for H2O
Yes
looks good