Decision Summary

Upload-ready calibration protocol overview
Instrument P288s1
Session 4
Location -
Calibration person Leonie Haunold
CF file Pandora288s1_CF_v4d20250724.txt
Software version 1.8.92
Calibration vector calV2
Reference day -
Overall status development
O3Ext: Not answeredO3Synt: Not answeredNO2: Not answeredSO2: Not answeredHCHO: Not answeredH2O: Not answered
Instrument P288s1
Session 4
Events 36
Figures 17
Action time 2m 9s

Action Timeline

9 action intervals
Apr 08, 202608:56 AM12:25 PMWavelengthCalibrationTempDependenceConvolutionAssignCalFileWavelengthCalibration 31s finishedWavelengthCalibration 11s finishedTempDependence 4s abortedConvolution 45s finishedConvolution 0s finishedConvolution 0s finishedConvolution 0s finishedConvolution 0s finishedAssignCalFile 38s finished

Duration by Step

Convolution45sWavelengthCalibration42sAssignCalFile38sTempDependence4s

Action Summary

Action Events Runs Aborted Time
AssignCalFile 3 1 0 38s
Convolution 16 5 0 45s
No action 9 0 0 0s
TempDependence 2 1 1 4s
WavelengthCalibration 6 2 0 42s

Session Figures

17 figures from Google Drive/figures
calprotocol section

Wavelength Calibration

Slit function parameters

Pandora288s1_WavelengthCalibration_SlitFuncParam.jpeg - 118 KB
Slit function parameters
reference period

Reference Day Decision Support

Upload the FOV and L0 raw-count evidence used to justify the selected reference day before reviewing the CreateReference figures.

calprotocol section

Reference Period and CreateReference

Create reference L1CHARFILT

Pandora288s1_CreateReference_L1CHARFILT_OPEN_U340.jpeg - 152 KB
Create reference L1CHARFILT

Create reference SELSPECS

Pandora288s1_CreateReference_SELSPECS_OPEN_U340.jpeg - 125 KB
Create reference SELSPECS

Create reference SLERR (STRAY)

Pandora288s1_CreateReference_SLERR(STRAY)_OPEN_U340.jpeg - 126 KB
Create reference SLERR (STRAY)

Create reference AODEST

Pandora288s1_CreateReference_AODEST.jpeg - 57 KB
Create reference AODEST

Create reference SENSCORRFIN (SENS)

Pandora288s1_CreateReference_SENSCORRFIN(SENS)_OPEN_U340.jpeg - 112 KB
Create reference SENSCORRFIN (SENS)

Create reference DISPFIT (DISP)

Pandora288s1_CreateReference_DISPFIT(DISP).jpeg - 118 KB
Create reference DISPFIT (DISP)

Create reference WLCHANGE (DISP)

Pandora288s1_CreateReference_WLCHANGE(DISP)_OPEN_U340.jpeg - 110 KB
Create reference WLCHANGE (DISP)

Create reference SHIFT (CLOS)

Pandora288s1_CreateReference_SHIFT(CLOS)_OPEN_U340.jpeg - 118 KB
Create reference SHIFT (CLOS)
field calibration

O3

FieldCalibration VC O3

Pandora288s1_FieldCalibration_VC_O3.jpeg - 99 KB
FieldCalibration VC O3

FieldCalibration SCREFINT O3

Pandora288s1_FieldCalibration_SCREFINT_O3.jpeg - 75 KB
FieldCalibration SCREFINT O3
field calibration

NO2

FieldCalibration MLE NO2

Pandora288s1_FieldCalibration_MLE_NO2.jpeg - 132 KB
FieldCalibration MLE NO2

FieldCalibration VCMLE NO2

Pandora288s1_FieldCalibration_VCMLE_NO2.jpeg - 72 KB
FieldCalibration VCMLE NO2
field calibration

SO2

FieldCalibration MLE SO2

Pandora288s1_FieldCalibration_MLE_SO2.jpeg - 71 KB
FieldCalibration MLE SO2

FieldCalibration VCMLE SO2

Pandora288s1_FieldCalibration_VCMLE_SO2.jpeg - 59 KB
FieldCalibration VCMLE SO2
field calibration

HCHO

FieldCalibration MLE HCHO

Pandora288s1_FieldCalibration_MLE_HCHO.jpeg - 71 KB
FieldCalibration MLE HCHO

FieldCalibration VCMLE HCHO

Pandora288s1_FieldCalibration_VCMLE_HCHO.jpeg - 65 KB
FieldCalibration VCMLE HCHO

Automatically harvested metadata

Automatically Harvested Metadata

Manual review and decision

Manual Review and Decision

Calibration notes, data-quality findings, and whole-period evaluation.

Data Evaluation

Could there be an offset between VPs?

No

Are there breakpoint-analysis plots or suspicious discontinuities?

No

Do daily figures before and after the new VP look consistent?

No

Is there an AMF dependency for one or more VPs?

No

Is there seasonality, for example negative values in winter?

No

Does the daily shape follow the trop data roughly?

No

If there is a discrepancy, what are the DS and Sky viewing directions?

No

Is there a co-located or nearby instrument for comparison?

No

O3Ext

Decision for O3Ext

O3Synt

Decision for O3Synt

NO2

Decision for NO2

SO2

Decision for SO2

HCHO

Decision for HCHO

H2O

Decision for H2O