Decision Summary

Upload-ready calibration protocol overview
Instrument P170s1
Session 11
Location -
Calibration person Leonie Haunold
CF file Pandora170s1_CF_v12d20231109.txt
Software version 1.8.58
Calibration vector calV4
Reference day -
Overall status development
O3Ext: Not answeredO3Synt: Not answeredNO2: Not answeredSO2: Not answeredHCHO: YesH2O: Not answered
Instrument P170s1
Session 11
Events 28
Figures 17
Action time 13m 11s

Action Timeline

10 action intervals
May 04, 2026May 05, 202607:07 PM06:33 AMFieldCalibrationAssignCalFileFieldCalibration 8s abortedFieldCalibration 1m 40s abortedFieldCalibration 1m 4s finishedFieldCalibration 0s abortedFieldCalibration 15s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedFieldCalibration 0s finishedAssignCalFile 10m 4s finished

Duration by Step

AssignCalFile10m 4sFieldCalibration3m 7s

Action Summary

Action Events Runs Aborted Time
AssignCalFile 3 1 0 10m 4s
FieldCalibration 16 9 3 3m 7s
No action 9 0 0 0s

Session Figures

17 figures from Google Drive/figures
calprotocol section

Wavelength Calibration

Slit function parameters

Pandora170s1_WavelengthCalibration_SlitFuncParam.jpeg - 126 KB
Slit function parameters
reference period

Reference Day Decision Support

Upload the FOV and L0 raw-count evidence used to justify the selected reference day before reviewing the CreateReference figures.

calprotocol section

Reference Period and CreateReference

Create reference L1CHARFILT

Pandora170s1_CreateReference_L1CHARFILT_OPEN_U340.jpeg - 116 KB
Create reference L1CHARFILT

Create reference SELSPECS

Pandora170s1_CreateReference_SELSPECS_OPEN_U340.jpeg - 90 KB
Create reference SELSPECS

Create reference SLERR (STRAY)

Pandora170s1_CreateReference_SLERR(STRAY)_OPEN_U340.jpeg - 90 KB
Create reference SLERR (STRAY)

Create reference AODEST

Pandora170s1_CreateReference_AODEST.jpeg - 46 KB
Create reference AODEST

Create reference SENSCORRFIN (SENS)

Pandora170s1_CreateReference_SENSCORRFIN(SENS)_OPEN_U340.jpeg - 88 KB
Create reference SENSCORRFIN (SENS)

Create reference DISPFIT (DISP)

Pandora170s1_CreateReference_DISPFIT(DISP).jpeg - 99 KB
Create reference DISPFIT (DISP)

Create reference WLCHANGE (DISP)

Pandora170s1_CreateReference_WLCHANGE(DISP)_OPEN_U340.jpeg - 98 KB
Create reference WLCHANGE (DISP)

Create reference SHIFT (CLOS)

Pandora170s1_CreateReference_SHIFT(CLOS)_OPEN_U340.jpeg - 110 KB
Create reference SHIFT (CLOS)
field calibration

O3

FieldCalibration VC O3

Pandora170s1_FieldCalibration_VC_O3.jpeg - 77 KB
FieldCalibration VC O3

FieldCalibration SCREFINT O3

Pandora170s1_FieldCalibration_SCREFINT_O3.jpeg - 53 KB
FieldCalibration SCREFINT O3
field calibration

NO2

FieldCalibration MLE NO2

Pandora170s1_FieldCalibration_MLE_NO2.jpeg - 133 KB
FieldCalibration MLE NO2

FieldCalibration VCMLE NO2

Pandora170s1_FieldCalibration_VCMLE_NO2.jpeg - 86 KB
FieldCalibration VCMLE NO2
field calibration

SO2

FieldCalibration MLE SO2

Pandora170s1_FieldCalibration_MLE_SO2.jpeg - 78 KB
FieldCalibration MLE SO2

FieldCalibration VCMLE SO2

Pandora170s1_FieldCalibration_VCMLE_SO2.jpeg - 79 KB
FieldCalibration VCMLE SO2
field calibration

HCHO

HCHO E-MLE settings applied fw1out=(); fw2out=(); dqf2in=(); ddlim=(-1.000,-1.000); shilim(nm)=(-0.050,0.050); uscmax=4.954e-04; wrmsmax=9.000e-04; atvarmax(%)=2.000e+01; amflim=(1.000,3.000); amflimvar=(0.000,1.000); perc=50.00; ngroup=10; timeaver(min)=0.00; redu=2; scref=(2.001e-04); uscref=(2.079e-05)

FieldCalibration MLE HCHO

Pandora170s1_FieldCalibration_MLE_HCHO.jpeg - 65 KB
FieldCalibration MLE HCHO

FieldCalibration VCMLE HCHO

Pandora170s1_FieldCalibration_VCMLE_HCHO.jpeg - 88 KB
FieldCalibration VCMLE HCHO

Automatically harvested metadata

Automatically Harvested Metadata

Manual review and decision

Manual Review and Decision

Calibration notes, data-quality findings, and whole-period evaluation.

Data Evaluation

Could there be an offset between VPs?

No

Are there breakpoint-analysis plots or suspicious discontinuities?

No

Do daily figures before and after the new VP look consistent?

No

Is there an AMF dependency for one or more VPs?

No

Is there seasonality, for example negative values in winter?

No

Does the daily shape follow the trop data roughly?

No

If there is a discrepancy, what are the DS and Sky viewing directions?

No

Is there a co-located or nearby instrument for comparison?

No

O3Ext

Decision for O3Ext

O3Synt

Decision for O3Synt

NO2

Decision for NO2

SO2

Decision for SO2

HCHO

Decision for HCHO
Yes
correction of sc

H2O

Decision for H2O