Decision Summary
Upload-ready calibration protocol overview
Instrument
P150s1
Session
101
Location
-
Calibration person
-
CF file
-
Software version
1.8.12
Calibration vector
-
Reference day
-
Overall status
development
O3Ext: Not answeredO3Synt: Not answeredNO2: Not answeredSO2: Not answeredHCHO: Not answeredH2O: Not answered
Action Timeline
No start/finish intervals found.No timeline intervals found
Duration by Step
No completed durations found
Action Summary
| Action | Events | Runs | Aborted | Time |
|---|---|---|---|---|
| No actions loaded | ||||
Session Figures
7 figures from Google Drive/figures
calprotocol section
Wavelength Calibration
reference period
Reference Day Decision Support
Upload the FOV and L0 raw-count evidence used to justify the selected reference day before reviewing the CreateReference figures.
calprotocol section
Reference Period and CreateReference
Create reference L1CHARFILT
Pandora150s1_CreateReference_L1CHARFILT_OPEN_U340.jpeg - 131 KBCreate reference SELSPECS
Pandora150s1_CreateReference_SELSPECS_OPEN_U340.jpeg - 100 KBCreate reference SLERR (STRAY)
Pandora150s1_CreateReference_SLERR(STRAY)_OPEN_U340.jpeg - 92 KBCreate reference AODEST
Pandora150s1_CreateReference_AODEST.jpeg - 38 KBCreate reference SENSCORRFIN (SENS)
Pandora150s1_CreateReference_SENSCORRFIN(SENS)_OPEN_U340.jpeg - 106 KBCreate reference WLCHANGE (DISP)
Pandora150s1_CreateReference_WLCHANGE(DISP)_OPEN_U340.jpeg - 98 KBAutomatically harvested metadata
Automatically Harvested Metadata
Manual review and decision
Manual Review and Decision
Calibration notes, data-quality findings, and whole-period evaluation.Data Evaluation
Could there be an offset between VPs?
No
Are there breakpoint-analysis plots or suspicious discontinuities?
No
Do daily figures before and after the new VP look consistent?
No
Is there an AMF dependency for one or more VPs?
No
Is there seasonality, for example negative values in winter?
No
Does the daily shape follow the trop data roughly?
No
If there is a discrepancy, what are the DS and Sky viewing directions?
No
Is there a co-located or nearby instrument for comparison?
No
O3Ext
Decision for O3Ext
relatively high uncertainty (~0.0015mol/m^2) whcih is due to the relatively high AtmVar for the reference. Due to the bad weather in the clearing period no better ref day was available. No extrapolation for the double differences was needed.
O3Synt
Decision for O3Synt
NO2
Decision for NO2
ok
SO2
Decision for SO2
slightly negative but since a re-calibration at the final destination will be done anyway this has not been improved for the clearing CF
HCHO
Decision for HCHO
looks quite good for the clearing period, could catch peaks which the trop data have also measured.
H2O
Decision for H2O